Heat Transfer Plates are used in so called “staple up systems” where the floor is warmed by placing heating tubes underneath the floor.
If you want to learn more, please visit our website Mufeng.
Aluminum material wraps around the heating tube and then spreads out and attaches to the under side of the heated floor.
Heat transfer plates perform three important functions.
There are differences of opinion about how much aluminum should be used, how thick it should be and even if aluminum is necessary at all.
Here, we will offer to you the benefit of our research and experience so that you can either understand our recommendation better, or make up your own mind.
RADIANTEC HAS CAREFULLY RESEARCHED THE PROPERTIES OF ALUMINUM PLATES TO HELP YOU MAKE THE BEST DECISIONS.HEAT TRANSFER – The purpose of your radiant heating system will be to make heat in the form of warm water (in an efficient manner, we hope) and then transfer that heat to your floor. Some process must take that heat away from the tubing and apply it to the underside of the floor so that the floor can heat the area above. Aluminum is a material that transfers heat exceptionally well but it is expensive, and its use should be carefully balanced against other methods of doing the same thing, and its application should be optimized for performance and cost effectiveness.
NO ALUMINUM vs. FULL COVERAGE OF ALUMINUM – Controlled experiments have shown that covering the tubing with medium/thin gauge aluminum plates causes the system to put out about 60% more heat when operated at the same temperature.
If you use no aluminum at all, you must either raise temperature of the fluid in the tubes to a very high level, use more tubing, or both. It is not desirable to operate plastic heat exchanger tubing at high temperatures for reasons of safety, efficiency and service life.
DIRECTION OF HEAT FLOW – Heat that goes in the wrong direction is called “BACKLOSS”.
The aluminum heat transfer plates have a unique and generally unappreciated property. Aluminum has what is called “low emissivity”. The emissivity of aluminum is .05 vs. .95 for ordinary materials. That means that when aluminum is warm, it emits radiant energy at a much lower rate than most other materials (only 5% as much).
These two images show how aluminum plates can significantly affect the performance of a “staple up” type system.
For more information, please visit Aluminum plate for floor heating.
The image on the left is an ordinary photograph of the underside of a floor that has radiant heating tubes that are fully covered with aluminum heating plates.
The image on the right is an infrared thermograph of the same situation. Yellow and red colors indicate higher emission of heat energy while blue indicates lower emission of heat energy. All materials are about the same temperature in this case (110°F).
The aluminum plates, which are about 110°F are emitting heat in the downward direction (backloss) as if they were only 60°F. This property has a very positive and generally unappreciated effect on the overall performance of a “staple up” system.SHAPE AND THICKNESS OF THE ALUMINUM PLATE – Aluminum heat transfer plates are available in any number of configurations and a decision must be made about which is ideal. Aluminum is expensive and the cost of installation is important as well. These photographs show some options.
A thicker aluminum stock will transfer heat faster than lighter stock. The extruded tubing groove fits tighter to the plastic tube for better contact. Overall, the thicker heavy gauge aluminum plate is 6% more efficient at transferring heat than the lighter gauge pre stamped aluminum plate. However, the heavy gauge material is four times as costly as the lighter gauge material. Also, it must be pre-drilled and screwed to the sub floor and the overall cost is much higher than that of the lighter material. The smaller size means that the low emissivity property of the aluminum will be less.
The lighter gauge pre-stamped material is economical enough to be used more thoroughly. It is thick enough to provide good heat transfer and thin enough to be stapled into place instead of drilling and screwing. The thickness is a little thicker than premium flashing but it is pure aluminum and it undergoes a heat treating process that makes it more malleable (called dead soft) so that it can be worked with easier.
The flat stock is for special applications. The material is malleable enough to be bent into custom shapes.
Heavy duty aluminum foil, available from the supermarket is at the other extreme. However, it is not really thick enough to transmit heat well and is little better than nothing.
RESULTS – Our data suggests that the options of no aluminum plates at all, heavy duty aluminum plates, and aluminum foil can generally be ruled out. The real decision is between a continuous covering of the tubing with a medium/light gauge aluminum stock, or an intermittent covering of half of the tubing. We have arrived at the following recommendations:
If heat loss downward (backloss) is entirely wasted as to a crawl space or basement, cover the tubes entirely and insulate well. If heat loss downward is useful to another space, then a reduction in aluminum by half should be considered.If the flooring material is thick or carpeted, the tubing should be covered entirely.
If low operating temperatures are desired, as for solar heating applications or for very high efficiency, or for other reasons, cover the tubing entirely.
Contact us to discuss your requirements of Underfloor Reflective Film. Our experienced sales team can help you identify the options that best suit your needs.