There are many types of commercial and industrial mechanical pipe insulation types to choose from. Each type offers advantages and disadvantages depending on the application. Determining owner project and performance requirements will simplify the product selection process while ensuring that the right pipe insulation is specified and installed to ensure long-term system performance.
For more information, please visit huamei.
This post will focus on closed-cell pipe insulation options, and more specifically, a focus on flexible rubber versus foam pipe insulation: which is better? Both consist of a closed-cell structure which efficiently controls condensation on below-ambient (cold) piping systems.
Flexible elastomeric closed-cell foam pipe insulation, also known as rubber, is composed of synthetic rubber. The two main foam rubber formulations that are commercially available are nitrile butadiene rubber with PVC (NBR/PVC) and EPDM (Ethylene Propylene Diene Monomer). The industry reference standard is ASTM C 534, Standard Specification for Preformed Flexible Elastomeric Cellular Thermal Insulation in Sheet and Tubular Form. A comparison between NBR/PVC and EPDM is available in a later section of this post.
In addition to foam rubber pipe insulation, another alternative is known as foam plastic (also known as polyethylene, polyolefin, poly, or PE). Foam plastic pipe insulation is often installed on residential and light commercial piping systems. The industry reference standard is ASTM C , Standard Specification for Extruded Preformed Flexible Cellular Polyolefin Thermal Insulation in Sheet and Tubular Form.
Rubber Versus Foam Pipe Insulation: Which is better?
Choosing between foam rubber and foam plastic depends on the application. Below are a few key performance characteristics to evaluate:
Thermal conductivity – foam rubber typically offers a lower (favorable, more thermally-efficient) K-value than foam plastic.
Continuous service temperature – foam plastic’s upper continuous temperature threshold is 200°F [93℃]; NBR/PVC foam rubber is 220℉ [104℃]; EPDM foam rubber is 257℉ [125℃].
Fire safety – this criteria is important to pay attention to. Foam rubber usually passes ASTM E 84 or UL 723 25/50 flame spread/smoke-developed index up to 2” [50 mm] thick. However, foam plastic has been known to melt, drip, or delaminate during the same test procedure. In other words, foam plastic’s fire performance is less predictable and in some cases does not pass at greater thicknesses such as 1-½” [38 mm] and 2” [50 mm].
Density – both foam pipe insulations are considered flexible, however foam plastic is more rigid by comparison.
Cost – foam plastic typically costs less than rubber, however the project application, performance characteristics, and owner project requirements may be more important than first cost.
A safe conclusion when comparing rubber versus foam plastic pipe insulation is that rubber is the better choice for commercial and industrial applications due to its lower thermal conductivity, higher continuous operating temperature, and more predictable fire behavior. Rubber is more likely to check all of the boxes when addressing the building owner’s project requirements.
To drill this comparison down another level, what should you look for when comparing NBR/PVC and EPDM foam rubber insulation? Both meet ASTM C 534, are made from synthetic rubber compounds and consist of a closed-cell structure and smooth outer skin that serves as a vapor barrier. But what are the performance advantages of Aeroflex® EPDM versus NBR/PVC?
Chemical Polarity – Aeroflex® EPDM is nonpolar (hydrophobic), which means that it does not induce or react to moisture. NBR/PVC is hygroscopic or attracted to moisture.
Thermal conductivity – Aeroflex® EPDM k-values are the same across core product lines.
Water vapor permeability (WVP) – Aeroflex® EPDM maintains low WVP across core product lines.
Corrosiveness – Aeroflex® EPDM is non corrosive on metallic piping, including stainless steel.
Continuous operating temperature (upper limit) – 257℉ [125℃].
UV resistance – Aeroflex® EPDM is more UV-resistant than NBR/PVC; although not UV-proof, EPDM will degrade at a slower rate than NBR/PVC.
Mold resistance – Aeroflex® EPDM does not contain organic food sources such as binder and oils which can sustain microbes; the addition of EPA-registered antimicrobials are necessary.
PVC content – for building owners seeking PVC-free building materials, Aeroflex® EPDM contains ultra-low PVC content (< 1% by weight).
If you are looking for more details, kindly visit rubber foam insulation.
Flexibility (cold weather) – EPDM is known to stay more flexible than NBR/PVC during cold-weather installations.
To learn more about Aeroflex® EPDM, click here.
High-density foam rubber sheets are a common industrial material with many unique properties and wide application fields.This article will detail the advantages and disadvantages of high-density foam rubber sheets to help readers better understand this material.
Advantages
1.High wear resistance:
One of the notable advantages of high-density foam rubber sheets is their excellent wear resistance.Due to their high-density structure,these rubber sheets perform well in heavy-load or high-wear environments,such as factory workshops and mining machinery.This makes high-density rubber sheets the preferred choice in applications requiring long-term durability.
2.Excellent shock absorption:
High-density foam rubber sheets have good elasticity and shock absorption capabilities,effectively absorbing impact forces and reducing vibration transmission.This characteristic makes them widely used in the automotive industry,building insulation,and sports venues.By using high-density foam rubber sheets,the operational stability and service life of equipment can be significantly improved.
3.Good thermal and sound insulation:
Due to the numerous closed pores within them,high-density foam rubber sheets have excellent thermal and sound insulation properties.These characteristics make them play a crucial role in applications requiring stable temperatures or noise reduction,such as building insulation layers and soundproof walls.
4.Chemical resistance:
This material also has high chemical resistance,capable of withstanding the erosion of various chemicals,making it suitable for the chemical industry and laboratory environments.The chemical resistance of high-density foam rubber sheets ensures their performance remains good even under harsh conditions.
Disadvantages
1.Poor flexibility:
Compared to low-density rubber sheets,high-density foam rubber sheets have relatively low flexibility.In applications with special requirements for softness and elasticity,such as sports venues and hospitals,high-density rubber sheets may not be suitable.In such environments,softer materials are usually needed to ensure comfort and safety.
2.Higher cost:
The production process of high-density foam rubber sheets is complex,and the raw material costs are also high,resulting in a relatively high market price.For projects with limited budgets,this can be a disadvantage.Therefore,when choosing rubber sheets,it is necessary to consider the cost-benefit balance.Sometimes,medium-density rubber sheets may be a compromise choice,meeting certain strength and wear resistance requirements while maintaining good economic efficiency.
3.Difficult processing:
High-density rubber sheets are relatively hard and difficult to process.Special equipment and techniques are required,increasing processing costs and time.If the processing technology is not up to standard,it may affect the overall performance of the product.Therefore,when choosing a supplier,it is necessary to ensure they have sufficient processing capabilities and technical experience.
High-density foam rubber sheets have obvious advantages in wear resistance,shock absorption,thermal and sound insulation,and chemical resistance,making them suitable for various industrial and commercial applications.However,their poor flexibility,higher cost,and difficult processing also need to be considered in practical applications.
The correct approach is to make the most suitable choice based on specific needs and usage environments,taking into account all factors to ensure both functional requirements and economic benefits are met.